ugg boots

Kundinger Controls
Analytical Process Systems

Canister Pressure
|
800-899-1885
fax: 248-391-6900
 

Canister Pressure Drop System CPDS-1000

What's the Pressure Drop Across Your Carbon Canister?

The APS CPDS-1000 test stand is designed for manual control of pressure and flow for testing carbon canister pressure drop values. This system tests load and purge modes by utilizing a compressed air supply and a vacuum pump. Test functions of the CPDS are:

  • Load or fill mode simulation by applying pressure to the canister load or tank port.
  • Purge mode simulation by applying vacuum to the purge port.
  • Canister weight determination on the optional scale.

Canister Pressure Drop SystemThe CPDS can be used for the following tests:

  • Purge Vacuum Drop
    -    Measures the total allowable purge vacuum drop across the carbon canister.
  • Loading Pressure Drop
    -     Diurnal (Enhanced Evaporative) - measures the total pressure drop across the carbon canister.
    -     Refueling (ORVR) - measures the total allowable air and tank tube pressure drop across the carbon canister.
  • Purge Restriction
    -      Measures the total allowable purge vacuum restriction across the carbon canister for enhanced evaporative and ORVR.

Optional features:

  • Fully automatic control and data acquisition system
  • Full integration with APS C2K (Canister Conditioning System)
  • Fixed-in-place or portable units

 
Technical Specifications


System power requirements

  • Voltage: 120VAC 60Hz, Single Phase
  • Current: 5 AMPS

Capabilities

  • Maximum purge flow rate: 100 slm
  • Maximum fill flow rate: 100 slm
  • Maximum vacuum reading: -25 in. wc
  • Maximum pressure reading: +25 in. wc
  • Scale capacity: 7.2 kg with 0.1 g resolution

Accuracy

  • Mass flow meter: +/- 1% of full scale
  • Differential pressure transmitters: +/- 0.25% of full scale

Purge vacuum pump

  • Rating: 4 cfm at -14 in. Hg

Compressed air

  • Maximum pressure: 120 psig
  • Minimum pressure: 90 psig at 5 scfm

Operating Temperature

  • Maximum ambient temperature: 105°F

Plumbing connections

  • Compressed air: 1/2" OD
  • Exhaust vent: 1" PVC

Canister connections

  • Pressure load port and pressure transducers: 1/4" OD, stainless steel
  • Vacuum purge port: 3/8" OD, stainless steel
  • Mass flow meter ports - 1/2" OD, stainless steel

Downloads

 
Home | 50 Years | Kundinger Controls Products | APS Products | About Us | Downloads | FAQs | News | Contact Us